Validation of color Doppler ultrasound and computed tomography in the radiologic assessment of non-malignant acute splanchnic vein thrombosis

Sturm, Lukas and Bettinger, Dominik and Klinger, Christoph and Krauss, Tobias and Engel, Hannes and Huber, Jan Patrick and Schmidt, Arthur and Caca, Karel and Thimme, Robert and Schultheiss, Michael and Chaireti, Roza (2021) Validation of color Doppler ultrasound and computed tomography in the radiologic assessment of non-malignant acute splanchnic vein thrombosis. PLOS ONE, 16 (12). e0261499. ISSN 1932-6203

[thumbnail of journal.pone.0261499.pdf] Text
journal.pone.0261499.pdf - Published Version

Download (1MB)

Abstract

Introduction
International guidelines propose color Doppler ultrasound (CDUS) and contrast-enhanced computed tomography (CT) as primary imaging techniques in the diagnosis of acute splanchnic vein thrombosis. However, their reliability in this context is poorly investigated. Therefore, the aim of our study was to validate CDUS and CT in the radiologic assessment of acute splanchnic vein thrombosis, using direct transjugular spleno-portography as gold standard.

Materials and methods
49 patients with non-malignant acute splanchnic vein thrombosis were included in a retrospective, multicenter analysis. The thrombosis’ extent in five regions of the splanchnic venous system (right and left intrahepatic portal vein, main trunk of the portal vein, splenic vein, superior mesenteric vein) and the degree of thrombosis (patent, partial thrombosis, complete thrombosis) were assessed by portography, CDUS and CT in a blinded manner. Reliability of CDUS and CT with regard to portography as gold standard was analyzed by calculating Cohen’s kappa.

Results
Results of CDUS and CT were consistent with portography in 76.6% and 78.4% of examinations, respectively. Cohen’s kappa demonstrated that CDUS and CT delivered almost equally reliable results with regard to the portographic gold standard (k = 0.634 [p < 0.001] vs. k = 0.644 [p < 0.001]). In case of findings non-consistent with portography there was no clear trend to over- or underestimation of the degree of thrombosis in both CDUS (60.0% vs. 40.0%) and CT (59.5% vs. 40.5%).

Conclusions
CDUS and CT are equally reliable tools in the radiologic assessment of non-malignant acute splanchnic vein thrombosis.